PERMIT-REQUIRED CONFINED SPACES

.

Permit-Required Confined Space Standard - General Requirements

Among other things, the OSHA standard requires the employer's written permit-required confined space program to:
  • Identify and evaluate permit space hazards before allowing employee entry
  • Test conditions in the permit space before entry operations and monitor the space during entry
  • Perform in the following sequence, appropriate testing for atmospheric hazards: oxygen, combustible gases or vapors, and toxic gases or vapors
  • Implement necessary measures to prevent unauthorized entry
  • Establish and implement the means, procedures and practices to eliminate or control hazards necessary for safe permit-space entry operations such as: specifying acceptable entry conditions, isolating the permit space, providing barriers, verifying acceptable entry conditions, purging, making inert, flushing, or ventilating the permit space.

Go to the next screen for more written standard requirements.